As a professional high quality Adjustable Over Voltage Current Protectors manufacturer, you can rest assured to buy Adjustable Over Voltage Current Protectors from our factory. And we will offer you the best after-sale service and timely delivery.Adjustable over voltage current protectors With Auto-Re closing Function (OUPA) is an intelligent protector integrated with over voltage protector, under voltage protector and over-current protector. In case of over-voltage fault, under-voltage fault or over-current fault in line, this product can instantly power off to prevent electrical equipment from being burnt. The over-voltage, under-voltage and over-current values of this product can all be set up by yourself and can be adjusted on the basis of local practical condition.
Wenzhou Changjiu Technology Co., Ltd. is a professional China Adjustable Over Voltage Current Protectors manufacturer and supplier, known for its quality service. Adhering to the pursuit of perfect quality of products, so that our Adjustable Over Voltage Current Protectors have been satisfied by many customers. In order to ensure the quality and customer needs, we have cooperated with domestic power groups with strong production strength. We will strictly screen each supplier and send videos to customers to watch.
Under voltage protection 210V-145V (adjustable) (default: 170V)
Over voltage proteciton 230V-300V (adjustable) (default: 270)
Over current protection 1A-63A (adjustable) (default: 40A)
Reconnect time (delay on time): 3s-300s (default: 30s)
Voltage meter , Ammeter
Rated voltage: 220V; Frequency: 50Hz/60HZ
Over current protection: 1A-63A (adjustable) (default: 40A)
Under-voltage action switch-off value: 210V-145V (adjustable) (default: 170V)
Over-voltage action switch-off value: 230V-300V (adjustable) (default: 270)
Reconnect time (delay on time): 3s-300s (default: 30s)
Error in real-time current, voltage : ≤5%
Press and hold on the “set” key for 3s, entering into setting status;
When over voltage indicator lamp lights up, set up the over voltage value by pressing the “up” key or “down” key to increase or decrease the over voltage value which can be 230V-300V (default: 270V).
Press the “set” key, when under-voltage indicator lamp lights up, set up the under-voltage value by pressing the “up” key or “down” key to increase or decrease the under-voltage value which can be 145V-210V, (default: 170V).
Press the “set” key, when current indicator lamp lights up, set up the over-current value by pressing the “up” key or “down” key to increase or decrease the over-current value which can be 1A-63A (adjustable) (default: 40A).
After the setting, stay for 40s before powering on.
Press the “up” key and “down” key together to restore factory setting.
Normal use and installation conditions
Normal use conditions
Ambient air temperature
Ambient air temperature shall not be more than +55℃ and not less than -20℃ and the Altitude of the installation place shall not exceed 2000m.
Atmospheric conditions
Humidity
The relative air humidity at installation place shall not be more than 50% when the ambient air temperature is +40℃; Relative humidity may be high under low temperature condition. For instance, when the mean minimum temperature in the wettest month is +20℃, the mean maximum relative humidity in the month may reach 90%. Condensation produced due to temperature change shall be prevented by taking appropriate measure.
Protector can be vertically or horizontally mounted in cabinet. If specially required, it is necessary to make special order.
Protector shall be mounted in medium without risk of explosion. In the medium, there shall be no gas and conductive dust which are sufficient to corrode metal and affect insulation effect.
Protector shall be mounted in place that may not be invaded by rain and snow.