Reclosing Molded Case Circuit Breaker
  • Reclosing Molded Case Circuit BreakerReclosing Molded Case Circuit Breaker

Reclosing Molded Case Circuit Breaker

As a professional high quality Reclosing Molded Case Circuit Breaker manufacturer, you can rest assured to buy Reclosing Molded Case Circuit Breaker from our factory. And we will offer you the best after-sale service and timely delivery.CJ technogy series Reclosing Molded Case Circuit Breaker (referred to as leakage circuit breaker) is the latest generation of leakage circuit breaker products developed by our company in recent years with superior performance and complete functions. The product has won several national patents. It is suitable for low-voltage power grids with three-phase four-wire neutral point direct grounding (TT grounding system). It is used to provide indirect contact protection for personal electric shock hazard, and can also protect grounding faults, overcurrents, short circuits, etc. of lines or electricity.

Send Inquiry

Product Description

Wenzhou Changjiu Technology Co., Ltd. is a professional China Reclosing Molded Case Circuit Breaker manufacturer and supplier, known for its quality service. Adhering to the pursuit of perfect quality of products, so that our Reclosing Molded Case Circuit Breaker have been satisfied by many customers. In order to ensure the quality and customer needs, we have cooperated with domestic power groups with strong production strength. We will strictly screen each supplier and send videos to customers to watch.

CJ technogyseries intelligent residual current operated circuit breaker (referred to as leakage circuit breaker) is the latest generation of leakage circuit breaker products developed by our company in recent years with superior performance and complete functions. The product has won several national patents. It is suitable for low-voltage power grids with three-phase four-wire neutral point direct grounding (TT grounding system). It is used to provide indirect contact protection for personal electric shock hazard, and can also protect grounding faults, overcurrents, short circuits, etc. of lines or electricity.


Reclosing molded case circuit breaker Details:


Characteristics

The product has three types of common type, electronic adjustable type, and communication type.

1. Common type with residual current adjustable, auxiliary power supply over-voltage and under-current protection, automatic reclosing, residual current display, and action status indication. And other practical features.

2. The electronic adjustable type has the above functions and also increases the current setting function. The digital tube can also display the three-phase load current. In actual power consumption, the circuit breaker current can be set according to the size of the digital tube display power load. Setting value.

3. Communication: The communication type product is connected to the GPRS communication template, and can send the status message to the manager's mobile phone. (Communication type operation instructions are attached)


Specification

Dimensions

Installation size

A

B

E

H

G

c

d

100A

240

142

48

83

177

70

202

250A

240

142

48

83

177

70

202

400A

336.5

197.5

87

99

253

95

274

630A

336.5

197.5

87

99

253

95

274

630A, 800A

355

240

88

111

259

116

285

Normal working conditions

1 Ambient air temperature: -5 °C + 40 °C.

2 When the maximum humidity is +40 °C, the relative humidity of the air does not exceed 50%, and 90% is allowed at 20 °C; and the condensation on the surface of the product occasionally due to temperature changes is taken into consideration.

3 The altitude does not exceed: 2000 meters.

4 Pollution level: Level 3

5 Installation category: ‖

6 Power supply sine wave distortion is less than 5%

7 The installation site shall not exceed 5 times the earth's magnetic field in any direction of the external magnetic field.

No explosive or corrosive gas; no rain or snow; dry and ventilated.


Product model and meaning


Technical parameters

1 Rated voltage: 380V three-phase four-wire

2 Rated current: 100A frame: 40A 63A 80A 100A can be set; 250A frame: 100A 125A 140A 160A 180A 200A 225A 250A can be set; 630A (400A) frame 250A315A350A400A500A630A; 800A frame: 630A, 800A can be set

3 Rated frequency: 50Hz

4 rated residual operating current (mA: 0.05/0.1/0.2/03/0.5 can be set

5 Rated residual non-operating current (mA): 0.025/0.5/0.1/0.15/0.255.6 rated residual breaking time: <0.2s/0.5sS type/1sS type 57 delay reclosing time: 20-60s automatic reclosing 58 auxiliary power supply under voltage action value: single phase 168V ± 5% (automatically close after voltage returns to normal)

9 Auxiliary power supply overvoltage action value single phase 270V ± 5% (automatically close after voltage returns to normal)

10 Leakage action characteristics classification: AC type

11 Product Use Category A

12 This product complies with: GB14048.2


Shelf rank
Rated current (A)

Ultimate short circuit breaking capacity

Current (KA)

Voltage (V)

Power factor

Test procedure

100

50

1.05Un

0.3

0-t-00

250

50

1.05Un

0.3

0-t-00

400-630

50

1.05Un

0.3

0-t-00


The protection characteristics of overcurrent release are shown in Table 2.

Ambient air
temperature

Test current

Trip time

Status

1.05In

2h without tripping

Cold start

1.3In

2h tripping

Hot state begins

400-630

10In

<0.2

Cold or hot start


Product installation and function setting

1. Before power-on installation, put the power switch of the leakage circuit breaker in the “off” position! Green "point" is displayed in the opening and closing indication window.

2. The product should be installed vertically and fixed with screws through the mounting holes.

3 According to the rated current of the product, select the appropriate wire according to the standard (Table 3) and strictly follow the specified wiring. The circuit breaker indicates that the terminal 1, 3, 5, N are the power terminal of the main circuit, and the lower wiring is 2, 4, 6 , N is the load twist line end. The wire must be connected to the copper connector. After the wiring is completed, install the arc shield correctly.


Rated current value
(A)

40
50

63

80

100

125

160

180
200
225

250

315
350

400

Wire cross-sectional area
(mm)

10

16

25

35

50

70

95

120

185

240


Rated current value
(A)

Cable cross section

Copper row size

Quantity

Cross-sectional area mm²

Quantity

Size

500A

2

150

2

30x5

630A

2

185

2

40x5




Hot Tags: Reclosing Molded Case Circuit Breaker, China, Manufacturers, Suppliers, Factory, Quality, Price